Tag Archive for: electric valve

Posts

electric butterfly valve code naming method

Electric butterfly valve model preparation method, electric butterfly valve code naming method, only suitable in China.
With the increase in demand for valves in my country’s industrial manufacturing industry, electric butterfly valves have become a more prominent one among many valves. However, due to the wide variety of electric butterfly valves, and the difference in control modes and medium pressure and temperature, users often choose electric Uncertainty about butterfly valve models! In order to avoid such a situation, our company specially provides the electric butterfly valve model preparation instructions for your reference and understanding!

lug type butterfly valve, ductile iron, center lined,

lug type butterfly valve, ductile iron, center lined,

The electric butterfly valve model preparation instructions include the addition of additional conditions for the butterfly valve, the difference in connection methods, the upgrade of the transmission mode, the change of the structure, the level of valve pressure, and the requirements for temperature, pressure, corrosion and material. Hope It is helpful to everyone in the selection!
Model representation method of electric butterfly valve:
Additional codes for electric butterfly valves: BD thermal insulation butterfly valve, SD telescopic butterfly valve, TLD desulfurization butterfly valve, DH check butterfly valve, DKS fast butterfly valve, FDBD square louver butterfly valve;
The code of the butterfly valve: D represents the butterfly valve;
Transmission form code: manual (omitted), 3 means turbine drive, 6 means pneumatic drive, 7 means hydraulic, 9 means electric;
Connection code: 4 flange type, 6 welding, 7 pair clip type;
Code of structural form: 1 means centerline type, 2 means double eccentricity, 3 means triple eccentricity, 4 means variable eccentricity, 5 means single eccentricity;
Sealing material code: H stainless steel, X rubber, F polytetrafluoroethylene, FX composite rubber, M Monel alloy, Y cemented carbide, W valve body directly processed;
Pressure grade code: 10=PN1.0Mpa, 16=PN1.6, 25=PN2.5, 40=PN4.0, PN is the code of domestic pressure, MPA is the unit of pressure, one kilogram is equal to 0.1Mpa; Class150LB=1.6 mpa, 300LB=2.5-4.0mpa, Class is the American standard code, LB is the American standard pound unit.
Shell material code: C cast steel, P stainless steel 304, R stainless steel 316, AL special alloy steel, Z cast iron, Q ductile iron, N nylon. To
The above are common codes related to butterfly valves. For products that need to be customized due to special working conditions, they can be selected according to the design plan.
Electric butterfly valve model preparation instructions: D943H-16C Stainless steel electric flange hard-sealed butterfly valve

D943H-16C-metal seated stainless steel electric triple offset butterfly valve

D943H-16C-metal seated stainless steel electric triple offset butterfly valve

D: Represents butterfly valve;
9: Indicates that the transmission mode is electric;
4: The connection method is flange connection;
3: The structure is triple eccentric;
H: The sealing material is stainless steel;
16: Indicates that the nominal pressure is 1.6MPa;
P: Indicates that the valve body is made of stainless steel.
Related valve model: Pneumatic butterfly valve model Electric ball valve model Pneumatic ball valve model

TH Valve is a professional manufacturer of butterfly valvegate valvecheck valveglobe valveknife gate valve, ball valve with API, JIS, DIN standard, used in Oil, Gas, Marine industry, Water supply and drainage, fire fighting, shipbuilding, water treatment and other systems, with Nominal Diameter of DN50 to DN1200, NBR/EPDM/VITON, Certificates & Approvals: DNV-GL, Lloyds, DNV, BV, API, ABS, CCS. Standards: EN 593, API609, API6D

Related news/knowledge:
Pneumatic butterfly valve model name coding method;
Pneumatic globe valve model preparation method;
Pneumatic ball valve model preparation method;
Representation method of butterfly valve model

The difference and selection of electric valve and pneumatic valve

With the progress and continuous reform of the times, my country’s valve products have also been innovated with the change of the times. At present, in the valve market where environmental protection and safety are increasingly

ductile iron, DI, butterfly valve, manufacturer, center line, TH valve

ductile iron, DI, butterfly valve, manufacturer, center line, TH valve

demanded, the use of automatic control devices such as electric valves and pneumatic valves is gradually becoming impossible Optional. The use of self-control valves is more energy-saving, safer and more reliable. Compared with the traditional manual valve, the movement speed is faster than the ordinary valve, which not only reduces the manpower, but also greatly improves the work efficiency.
Compared with the pneumatic valve, the electric valve has a simple structure and reliable operation, and its power source (power source or air source) is easy to solve for the remote operation point. The disadvantage is that the price is higher and the explosion-proof requirements are also higher. When selecting, comprehensive consideration should be given to factors such as the

electric ball valve

electric ball valve

availability, price and control requirements of the power source. The selection of the valve generally first confirm the valve material, valve diameter, medium type, pipeline pressure, connection mode, control mode, medium temperature etc.

Electric valve selection: When electric valve is selected (the control mode of electric actuator is generally divided into on-off type and regulating type), in addition to the basic valve body diameter, pressure, material and other requirements, the following parameters should be provided:
1. Power supply parameters (including voltage, number of phases and frequency);

pneumatic ball valve

pneumatic ball valve

2. Running time and form of electric actuator;
3. Whether explosion-proof and explosion-proof grade are required;
4. Atmospheric protection level;
5. Overload protection requirements, such as over travel protection, over torque protection, etc.;
6. Local operation requirements, such as whether to bring a local operation handwheel;
7. Operation instruction requirements.
Pneumatic valve selection: When selecting pneumatic valves (the operating principle of pneumatic actuators can be divided into single-acting and double-acting), in addition to determining specific parameters such as valve body diameter, pressure, and material, the following parameters should also be provided:
1. Air source parameters (including air source pressure range, whether to bring your own gas storage tank, etc.)
2. Running time and form of pneumatic actuator
3. Whether explosion-proof and explosion-proof grade are required;
4. Atmospheric protection level;
5. Overload protection requirements, such as over travel protection, over torque protection, etc.;
6. Local operation requirements, such as whether to bring a local operation handwheel;
7. Operation instruction requirements.
As the level of industrial automation requirements has increased significantly, the demand for electric (pneumatic) valves is also increasing, and the control requirements for electric (pneumatic) valves have become more and more detailed and complex. For the correct selection of electric (pneumatic) valves, it not only involves the correct use of the product, but also may affect the safety of the entire pipeline system. Users should understand and understand the relevant selection knowledge.

TH Valve is a professional manufacturer of butterfly valvegate valvecheck valveglobe valveknife gate valve, ball valve with API, JIS, DIN standard, used in Oil, Gas, Marine industry, Water supply and drainage, fire fighting, shipbuilding, water treatment and other systems, with Nominal Diameter of DN50 to DN1200, NBR/EPDM/VITON, Certificates & Approvals: DNV-GL, Lloyds, DNV, BV, API, ABS, CCS. Standards: EN 593, API609, API6D

Related news/knowledge:
Applicable occasions and operation method of ball valve;
working principle of electric globe valve;
Notes on selection and installation of butterfly valve;
Description of electric valve connection

Description of electric valve connection

Electric valve wiring methods are classified according to different use requirements and different field conditions,

lug type butterfly valve, ductile iron, center lined,

lug type butterfly valve, ductile iron, center lined,

and the wiring methods used by electric actuators with different functions are also different. The user should have an understanding of the relevant knowledge of the wiring, so as to avoid unnecessary failures. On the one hand, the entire circuit will be short-circuited; On the other hand, it may cause huge economic losses caused by the burning of the machine, or even more serious Accident!

Electric valve actuators can generally be divided into AC (AC110V, AC220V, AC380V) and DC (DC24V, DC12V) according to the power supply voltage. According to the control method, they can be divided into active switch type, passive switch type, potentiometer type, explosion-proof type, and adjustable type Wait. (Related products: Electric switching butterfly valve, Electric regulating butterfly valve, Electric switching ball valve, Electric regulating ball valve)

Active switch type, common switch type with source indicator wiring diagram

Active switch type, common switch type with source indicator wiring diagram

Passive switch type, switch type passive contact type with feedback wiring diagram

Passive switch type, switch type passive contact type with feedback wiring diagram

Opening type potentiometer type, switch type with opening type wiring diagram

Opening type potentiometer type, switch type with opening type wiring diagram

Intelligent adjustment type, input and output 4-20mA, intelligent adjustment type wiring diagram

Intelligent adjustment type, input and output 4-20mA, intelligent adjustment type wiring diagram

AC 380V, with passive contact feedback, 380V power supply wiring diagram

AC 380V, with passive contact feedback, 380V power supply wiring diagram

DC24V, exchange of positive and negative switches and passive signal feedback, 24V power supply wiring diagram

DC24V, exchange of positive and negative switches and passive signal feedback, 24V power supply wiring diagram

Note: The above circuit diagram is for reference only, the actual circuit diagram attached to the product shall prevail. In addition, the electric devices of each manufacturer are different, and the wiring methods are also different. Please do not perform operations based on this standard. If a series of problems or related accidents occur, our company will not be responsible. !

TH Valve is a professional manufacturer of butterfly valvegate valvecheck valveglobe valveknife gate valve, ball valve with API, JIS, DIN standard, used in Oil, Gas, Marine industry, Water supply and drainage, fire fighting, shipbuilding, water treatment and other systems, with Nominal Diameter of DN50 to DN1200, NBR/EPDM/VITON, Certificates & Approvals: DNV-GL, Lloyds, DNV, BV, API, ABS, CCS. Standards: EN 593, API609, API6D

Related news /knowledge:
Pneumatic ball valve principle, structure and working principle;
Working principle diagram of electric butterfly valve;
Gate valve structure diagram and working principle;
What are the accessories for pneumatic valves?